Capture Functions
- Open assigned checks from My day, the engineer home screen, and work through each appliance. At the top of the check, Back to your jobs returns to My day on the web (the app has its Back button). The check shows the office’s Notes for this visit, whatever they are (a key safe code, parts waiting at the merchant), beside the property’s standing note, Property access, so the engineer sees what was written when the visit was booked as well as the usual way in. Under them, Practical notes lists the property’s field notes, the ones kept for next time and those marked Important first, above the appliances, on the web and in the app. Add a note for next time, under them, keeps a note on the property (tagged Technical / for next time, shown on every later job and check there); it is not General notes, which print on the certificate, and nothing is copied onto the certificate by itself. The Office-only notes field under More details on Schedule check, with “Engineers do not see this note.” under it, is for the office: it shows on the check page under Visit details, labelled Office-only notes, and never on an engineer screen. The Notes box on Schedule check (its hint reads Access, keys, parts to collect - the engineer sees this on their phone) is the one the engineer sees, on the check page, Prep and Route, and on a job booked from the phone the job screen shows it the same way. Notes and Office-only notes each take up to 5,000 characters; a counter appears as a note nears that, and a longer one is refused at its own field.
- In the property card, the check says First visit to this property in one line when there is no earlier visit by your firm there on record (imported history counts as a visit; no access does not), and above it Also a boiler service when the office booked one on the same visit, with the boiler’s make and model and whether to take a service kit. Both show on the web and in the app.
- Record each appliance’s results (safety devices, ventilation, flue or chimney), whether it is safe to use and whether a defect was identified. Readings and tests (CO ppm, CO₂ %, CO/CO₂ ratio, operating pressure, heat input, flue flow, spillage test, visual condition) sit behind a Readings & tests disclosure, open on the boiler when the visit includes a boiler service. Each card keeps PlateScan and FlueScan; Find the fault and the manufacturer’s support pack sit under Help with this appliance, and Find the fault stays on the card once one of its tests fails. An appliance’s own notes open from Add a note.
- Each appliance asks only for what its type takes, on the web and in the app: a hob has no flue check, flue flow or spillage test and no CO, CO₂ or ratio (or analyser scan); a cooker has no flue tests; a gas meter has its working pressure and condition; a room-sealed boiler, water heater or fire has no spillage test, and a flueless one no flue tests. Any other type, or an unclear flue type, asks for everything, and a reading already recorded always shows.
- Each appliance can record the CO alarm in its room, at the end of Readings & tests, on the web and in the app: CO alarm fitted (Yes, No or N/A) and, once Yes is chosen, the expiry date on the alarm and whether it was tested (Pass, Fail or Not tested). It is optional: left blank it never stops a save or Submit, and the section opens by itself when it holds an answer. In the app the date is typed as YYYY-MM-DD; one that is not a real date is named under the field and stops the save until it is put right, as a reading does. Changing Yes to No or N/A drops the date and the test. The certificate prints what was recorded.
- A reading no instrument could give is refused by its field, on every save, on the web and in the app: CO above 10,000 ppm, CO₂ above 20%, a CO/CO₂ ratio above 1, or an operating pressure above 2,000 mbar (that is 2 bar, so check the figure is in mbar). Heat input must be above 0 and at most 5,000 kW (5 MW), so a slipped decimal point or a figure in watts is refused. Heat input is optional: leave it blank when it is not known (a cooker often has no figure to read), and 0, N/A, - or unknown typed in it saves as not known rather than stopping the save. A reading is a plain number, typed with a point for the decimal and no unit, comma or exponent (1e3 is refused). CO₂ (%) sits beside CO and the ratio, as on a standard CP12, and prints on the certificate with them. Type CO and CO₂ and the ratio fills itself (CO ÷ 10,000 ÷ CO₂, to four decimal places); type your own ratio, or scan one with FlueScan, and it is left as you wrote it. FlueScan fills the CO₂ as well.
- An appliance whose CO is above 350 ppm, or whose ratio is above 0.0040 (the TB 143 action levels), is flagged on its card: Above the TB 143 action level: investigate before passing. The card names what is over. A Pass is never refused for it, but while the appliance reads Pass or Safe to use, Submit names it until you tick I have investigated: the manufacturer's figures allow these readings, so this appliance passes. Change a reading and the tick is asked for again. Save draft is never stopped by it.
- A check is dated the day of the visit, so a check date after today (UK time) is refused. On the web the date field says so and neither Save draft nor Submit sends; the native app, which has no date field, names it at Submit; the server refuses such a save (The check date cannot be in the future.); and the office cannot generate a record from it, so no certificate, renewal or property date is ever made from a mistyped year.
- Record defects and categorise them as At Risk, Immediately Dangerous, Not to Current Standards, or Other. The category starts blank and has to be chosen: a defect with none stops Submit, on the web and in the app.
- Marking an appliance Safe to use: No needs a defect on it classified as At Risk (AR) or Immediately Dangerous (ID). Not to Current Standards (NCS) and Other do not count. The card says so under the answer, and until it has one Submit stops and the record cannot be generated.
- Add photos as evidence, plus PlateScan and FlueScan assist for data plates and analyser readings. Photos never block submit; the checklist warns when a defect, an unsafe result or a no-access visit has no photo. A photo is shrunk on the phone, must then be 4 MB or under (JPEG, PNG or WebP), has its location and camera metadata stripped, and is tagged with a stage: on a check General evidence, Data plate, Flue reading and Parts, with Defect and Warning notice once a defect is recorded and No access on a no-access visit; a job report offers Before, During, After, Defect, Parts and General evidence.
- Record the parts and materials used, picked from van stock or captured with PartScan and CodeScan; see Parts, Van Stock, PartScan, and CodeScan.
- Draft structured notes and customer explanations with Manifold Assist; every draft is read and edited by you before it is used. On the check, Voice note and Tidy this note are buttons on the General notes box.
- Capture the engineer signature, which is required to submit, and the tenant signature, which is optional and shows once Tenant present?, asked at the top of the signatures, is Yes; both freeze into the immutable record. At a homeowner’s own home (no client, or a homeowner client) the question is Customer present? and the pad Customer signature, as the record words them, and the done screen sends the record to the homeowner with no landlord’s copy to ask for. Type it instead, under each pad, signs with a typed name for anyone who cannot draw one (a keyboard, a switch); the name is drawn into the signature as it would be by hand.
- Put right what was captured wrongly while the check is open (until its record is made): each photo has Remove, and each appliance has Correct or remove on its card (type, location, make, model, serial and GC number, changed on the register too). Inside it, No longer at the property (replaced or taken out) is for one that was there and has gone, such as a boiler replaced or a fire taken out: it comes off this check, every check after it and the property’s register, and its past checks, certificates and defects stay as they are. Remove this appliance (added by mistake or twice) takes one off the check and the register as if it was never added; one with history (on another check, or with a fault code, parts or an F-gas event logged against it) cannot be removed, so mark it No longer at the property instead. These need a signal: a photo still waiting on the phone can be removed offline. Save or cancel a correction before Save draft or Submit: until it is saved it is not on the check, so both ask for it first. A check sent back by a senior reviewer reopens with the serial and other details it was submitted with.
- Record the tightness test under IGEM/UP/1B Edition 4 (mandatory from 1 October 2026): fuel gas, what was connected, test pressure, gauge, the drop over the two-minute test, whether a smell of gas was reported and, where appliances were connected, the pipework-only retest. The card shows the permissible drop for the installation volume band and what the standard makes of the readings; you set Pass, Fail or Not applicable. A test pressure the standard does not test that fuel at is refused under the field, by the same bounds as the free calculator on the website: more than 1.5 times the usual pressure (20 mbar for natural gas, 37 for LPG, 21 for LPG/Air), or, for LPG and LPG/Air, under half of it (a low figure is judged once you leave the box). No reading is worked over a refused figure, and the check will not save, as a draft or a submit, until it is corrected. A pressure inside those bounds but unusual (LPG well under 37 mbar, say) is a warning, and the notes ask you to say why it was tested at that pressure; that never stops a save. The Landlord Gas Safety Record prints the result as one line. The card is open on every check where access was gained. Fuel gas starts filled in from the property’s register when every appliance’s gas type is known (change it if it is wrong), and the fuel you record fills in any gas type the register does not know yet, so the next visit starts with it; the result is always yours to set. The installation volume is asked for once the drop is perceptible (Add installation volume opens it before then), and the notes box opens for Not applicable, a Fail or an unusual test pressure (Add a note otherwise).
- A property on LPG: switch on LPG supply (it says so when the tightness test’s fuel is LPG; the switch is not offered when every appliance on the register is recorded as natural gas) and record the supply (cylinders or a bulk tank), the regulator, the hose and, if you know it, its replace-by date, the cylinder or tank location and ventilation, and the emergency control. Pass, Fail or N/A on each; Submit names any that are still blank. The certificate prints the supply and its title names LPG. Natural gas leaves it off and nothing changes.
- Work out the installation volume on the card: pipe runs by material and size, the meter, and valves and fittings (10% of the pipework unless you enter the actual volume). Hidden runs take the largest size you can see. The same calculator is free on the website for a test with no check open, and under Tools, in the bar at the bottom of the engineer’s screens in the app and on the web, as Tightness test (IGEM/UP/1B Ed 4), where nothing is saved.