Record Types
- Landlord Gas Safety Record (CP12), the core domestic certificate, with a CP12 reference prefix. For a homeowner (a property with no client, or a homeowner client) the same CP12 is titled Homeowner Gas Safety Record, in the PDF, the shared link and the emails, with the customer named under Homeowner, the signature box and “present” line saying Customer instead of Tenant, and no Tenant line; this holds for an older record of a homeowner’s home when it is downloaded again. A homeowner’s CP12 does not ask for a landlord or agent, since naming them is a landlord’s duty, and the engineer’s check, its done screen and the office’s check and job pages call the person there the homeowner or customer.
- Warning notice (CP14) where the check found an unsafe situation: an Immediately Dangerous or At Risk defect, or an appliance with a defect marked not safe to use. A check with neither (a Not to Current Standards defect alone, say) gets no CP14: the check page says why, and Generate refuses it.
- A CP14 is laid out as a warning notice: a DANGER: DO NOT USE or AT RISK: DO NOT USE heading, then only the unsafe appliances (and any unsafe part of the installation), each headed IMMEDIATELY DANGEROUS or AT RISK with its classification, what was found, the action taken and a do not use statement, the advice given, and the engineer's and the responsible person's signatures, or that they refused to sign or were not there, with the date and time it was issued. The engineer usually makes it on site from the screen after Submit; one the office makes prints the responsible person as Not recorded unless the engineer recorded them. A CP14 made before this layout keeps the layout it was issued with.
- Gas service records for service-only visits.
- A property on LPG records its supply on the check (cylinders or a bulk tank, the regulator, the hose and its replace-by date, the location, ventilation and the emergency control), and the Landlord Gas Safety Record prints it with LPG in its title. It is still a CP12, not a separate type.
- Jobs that are not gas safety checks file their own records from the job, not from this selector: a Breakdown and repair record (BR-), a Commissioning record (CM-), a Decommissioning record (DC-) or a job report (JR-). See Work: Every Visit in One Place.
- Every record opens with a summary under its header: the overall result in the record’s own words (Satisfactory, Unsatisfactory, Action required or Unable to complete), the date of the check, the next due date (the next gas safety check, service or commercial check; a warning notice has none), how many defects it records and the most serious class (Immediately Dangerous, then At Risk), and how many Not to Current Standards advisories it carries, when there are any. A CP12 also says when a warning notice was given. The full detail follows below, unchanged, in the PDF, on screen and on the record’s public link.
- Each appliance has a block of its own. Its top line prints its result and Safe to use (YES, NO or N/A), an appliance that is not safe to use has its block outlined in red, and, for an appliance with a defect, the block prints the action taken (Warning notice given, Appliance disconnected, Capped off and so on), as the engineer recorded them, with the defect class (AR, ID, NCS or NCS advisory) beside the result, never instead of it. An appliance with a failed test, a not safe to use answer or a defect other than Not to Current Standards reads Unsatisfactory; one whose only finding is an NCS defect, and that otherwise passed and is safe to use, reads Satisfactory with an NCS advisory. It reads the same on the check page, the live preview and the certificate. A record made before Safe to use was printed shows nothing for it rather than a guess.
- Every record prints the gas tightness test as one line from the check: result, the edition of IGEM/UP/1B it followed, the fuel gas and test pressure, and the drop, then the engineer’s note when there is one; a visit with no test recorded prints Not recorded. A Pass the Edition 4 table reads as a fail stands only with the engineer’s reason in the tightness notes.
- Each appliance block prints its type, location, flue type and GC number, and the engineer’s notes for that appliance. The defects listed are the ones the engineer submitted: a draft save writes none, and a defect removed before Submit is not printed.
- Each appliance prints its CO alarm on the line under its row when the engineer recorded one: Fitted, with the expiry date and the test (tested, pass; tested, fail; or not tested) as recorded, Not fitted, or N/A. Nothing prints for an appliance with no CO alarm answer, and a record issued before the CO alarm could be recorded prints as it always did.
- From 1 October 2026 (IGEM/UP/1B Edition 4) a check with no tightness test result is flagged on the check page before the record is made; for a visit from 1 November 2026 the Landlord Gas Safety Record cannot be generated without one, and every other certificate type shows the warning only. The visit’s date counts, not the day the record is made. Not applicable, with the reason in the notes, counts as a result and prints as Not applicable followed by that reason. A Pass after a first test the table read as a fail prints as Pass on retest, with the first drop, then the retest pressure and drop. A visit with no access, or marked Unable to complete, is exempt.
- Commercial records (CP16 and CP17) where the work is commercial rather than domestic. The selector offers them only on a property that is not a house, flat, maisonette or HMO (one already made is still listed).
- Only a CP12 moves the check to Record generated, updates the property’s compliance status and next-due date and each appliance’s status and last checked date, and sends the tenant copy. It books nothing for next year: the renewal comes up on the Call list from the new due date. CP14, service, CP16 and CP17 records are generated and referenced without changing the check. A CP14 Warning Notice carries no follow-up or next-due date: it records an unsafe situation, not an inspection that falls due again. A Landlord Gas Safety Record shows the landlord or agent’s name and address, so it is not made until the client has an address, and no certificate of any type is made from a visit where access was not gained.
- A Gas Service Record also sets the property’s Next boiler service due date, a year on from the visit, and its Last boiler service, which start the boiler service reminders (see Renewal Lifecycle and Reminders). They only move forward: a record for an earlier visit than the one the property already holds changes nothing. It never touches the gas safety due date, status or reminders. The record’s own Next service date is 12 months from the service, with no gas safety anniversary carried over.
- When the client is a letting agent or a property manager and the property names a landlord, a record prints the landlord’s name and address beside the agent: under Landlord / agent on screen, and in a Landlord column of its own on the printed certificate and the PDF. The landlord is fixed on the record when it is issued, so a record already issued never changes if the property is edited later, and a record from before this existed prints as it always did. A property whose client is the landlord, or a homeowner’s property, prints no landlord line. When the record’s client is a homeowner client, the column is headed Homeowner instead of Landlord / agent; a record with no client prints as it always did.
- Pick the certificate type in the selector beside Generate on the check page; a check can carry more than one type, such as a CP12 plus a CP14.
- When the certificate is made: as the engineer submits a signed check, for someone who works alone and for a team, unless the owner has switched on The office checks each certificate before it goes out under Settings, Gas safety certificates. With it on, the submitted check is flagged Certificate to issue in Needs attention on Today and Work, and the office generates it from the check page. A team engineer opens the certificate made at submit by its link (Open the certificate), and sends the landlord or agent their copy from the done screen.