Docs/Records, Defects, and Renewals

Gas Safety Records (CP12 and Cert Types)

Gas safety records are the certificate types Manifold generates, covering how immutability and delivery work for each.

For: Office teams17 min read5 sections
Record exampleCustomer-safe walkthrough

A record you can trust because it cannot quietly change

Manifold generates CP12 and related certificates from reviewed checks. They are immutable, idempotent per check, and render with a fixed document palette.

What you see

  • A record identifying the property, client, engineer, Gas Safe number, and appliances.
  • A clear outcome and the next-due date.
  • Download PDF on the record, and Download pack (PDF) under Gas certificates on the property.

How to use it

  • Confirm Business identity (Settings, then Organisation) and each engineer’s Gas Safe licence number (Settings, then Profile) before generating real records.
  • Choose the certificate type in the Certificate type selector beside the Generate button: Landlord Gas Safety Record, Warning Notice, Gas Service Record, or Commercial Gas Safety Record (CP16) or (CP17). The button follows your choice, for example Generate CP12.
  • Download a single record, or a record pack bundling a property’s 50 most recent certificates.
  • Deliver to tenant and client and confirm the delivery stamps.

Work Records

CP12-26-04821

Landlord Gas Safety Record

Satisfactory

12 Oakwood Road, Leeds

Northgate Lettings · A. Mercer, Gas Safe 512347

Download PDFSend to landlord/agent

Appliances & flues tested

Worcester Greenstar 30i

Boiler

Pass

Valor Black Beauty

Gas fire

Pass
Cannot be editedNext due 15 Jun 2027

Decision guide

SituationDomestic landlord check
Recommended actionGenerate the CP12 Landlord Gas Safety Record.
Proof it workedThe reference uses the CP12 prefix.
SituationAn appliance is dangerous
Recommended actionUse the warning-notice path alongside the record.
Proof it workedThe defect, action, and notice agree.
SituationCommercial work
Recommended actionPick CP16 or CP17 when generating.
Proof it workedThe correct certificate is produced.

Troubleshooting path

  1. 1If the certificate type is wrong, confirm the check type before generating.
  2. 2If a record pack is missing a certificate, confirm each check generated its record.
  3. 3If a PDF download fails, retry after confirming the record generated.

Generated record summary

Operational sample

Safe example data
reference: CP12-26-00042
property: 12 Oakwood Road, Leeds, LS6 2AB
client: Northgate Lettings
engineer: A. Mercer (Gas Safe 512347)
appliances: Worcester Greenstar 30i (pass), Valor Black Beauty (pass)
overall outcome: Satisfactory
next gas safety check due: 15 Jun 2027
The reference and identity block are fixed once generated.
A new check produces a new record; the old one is preserved as history.

Record Types

  • Landlord Gas Safety Record (CP12), the core domestic certificate, with a CP12 reference prefix. For a homeowner (a property with no client, or a homeowner client) the same CP12 is titled Homeowner Gas Safety Record, in the PDF, the shared link and the emails, with the customer named under Homeowner, the signature box and “present” line saying Customer instead of Tenant, and no Tenant line; this holds for an older record of a homeowner’s home when it is downloaded again. A homeowner’s CP12 does not ask for a landlord or agent, since naming them is a landlord’s duty, and the engineer’s check, its done screen and the office’s check and job pages call the person there the homeowner or customer.
  • Warning notice (CP14) where the check found an unsafe situation: an Immediately Dangerous or At Risk defect, or an appliance with a defect marked not safe to use. A check with neither (a Not to Current Standards defect alone, say) gets no CP14: the check page says why, and Generate refuses it.
  • A CP14 is laid out as a warning notice: a DANGER: DO NOT USE or AT RISK: DO NOT USE heading, then only the unsafe appliances (and any unsafe part of the installation), each headed IMMEDIATELY DANGEROUS or AT RISK with its classification, what was found, the action taken and a do not use statement, the advice given, and the engineer's and the responsible person's signatures, or that they refused to sign or were not there, with the date and time it was issued. The engineer usually makes it on site from the screen after Submit; one the office makes prints the responsible person as Not recorded unless the engineer recorded them. A CP14 made before this layout keeps the layout it was issued with.
  • Gas service records for service-only visits.
  • A property on LPG records its supply on the check (cylinders or a bulk tank, the regulator, the hose and its replace-by date, the location, ventilation and the emergency control), and the Landlord Gas Safety Record prints it with LPG in its title. It is still a CP12, not a separate type.
  • Jobs that are not gas safety checks file their own records from the job, not from this selector: a Breakdown and repair record (BR-), a Commissioning record (CM-), a Decommissioning record (DC-) or a job report (JR-). See Work: Every Visit in One Place.
  • Every record opens with a summary under its header: the overall result in the record’s own words (Satisfactory, Unsatisfactory, Action required or Unable to complete), the date of the check, the next due date (the next gas safety check, service or commercial check; a warning notice has none), how many defects it records and the most serious class (Immediately Dangerous, then At Risk), and how many Not to Current Standards advisories it carries, when there are any. A CP12 also says when a warning notice was given. The full detail follows below, unchanged, in the PDF, on screen and on the record’s public link.
  • Each appliance has a block of its own. Its top line prints its result and Safe to use (YES, NO or N/A), an appliance that is not safe to use has its block outlined in red, and, for an appliance with a defect, the block prints the action taken (Warning notice given, Appliance disconnected, Capped off and so on), as the engineer recorded them, with the defect class (AR, ID, NCS or NCS advisory) beside the result, never instead of it. An appliance with a failed test, a not safe to use answer or a defect other than Not to Current Standards reads Unsatisfactory; one whose only finding is an NCS defect, and that otherwise passed and is safe to use, reads Satisfactory with an NCS advisory. It reads the same on the check page, the live preview and the certificate. A record made before Safe to use was printed shows nothing for it rather than a guess.
  • Every record prints the gas tightness test as one line from the check: result, the edition of IGEM/UP/1B it followed, the fuel gas and test pressure, and the drop, then the engineer’s note when there is one; a visit with no test recorded prints Not recorded. A Pass the Edition 4 table reads as a fail stands only with the engineer’s reason in the tightness notes.
  • Each appliance block prints its type, location, flue type and GC number, and the engineer’s notes for that appliance. The defects listed are the ones the engineer submitted: a draft save writes none, and a defect removed before Submit is not printed.
  • Each appliance prints its CO alarm on the line under its row when the engineer recorded one: Fitted, with the expiry date and the test (tested, pass; tested, fail; or not tested) as recorded, Not fitted, or N/A. Nothing prints for an appliance with no CO alarm answer, and a record issued before the CO alarm could be recorded prints as it always did.
  • From 1 October 2026 (IGEM/UP/1B Edition 4) a check with no tightness test result is flagged on the check page before the record is made; for a visit from 1 November 2026 the Landlord Gas Safety Record cannot be generated without one, and every other certificate type shows the warning only. The visit’s date counts, not the day the record is made. Not applicable, with the reason in the notes, counts as a result and prints as Not applicable followed by that reason. A Pass after a first test the table read as a fail prints as Pass on retest, with the first drop, then the retest pressure and drop. A visit with no access, or marked Unable to complete, is exempt.
  • Commercial records (CP16 and CP17) where the work is commercial rather than domestic. The selector offers them only on a property that is not a house, flat, maisonette or HMO (one already made is still listed).
  • Only a CP12 moves the check to Record generated, updates the property’s compliance status and next-due date and each appliance’s status and last checked date, and sends the tenant copy. It books nothing for next year: the renewal comes up on the Call list from the new due date. CP14, service, CP16 and CP17 records are generated and referenced without changing the check. A CP14 Warning Notice carries no follow-up or next-due date: it records an unsafe situation, not an inspection that falls due again. A Landlord Gas Safety Record shows the landlord or agent’s name and address, so it is not made until the client has an address, and no certificate of any type is made from a visit where access was not gained.
  • A Gas Service Record also sets the property’s Next boiler service due date, a year on from the visit, and its Last boiler service, which start the boiler service reminders (see Renewal Lifecycle and Reminders). They only move forward: a record for an earlier visit than the one the property already holds changes nothing. It never touches the gas safety due date, status or reminders. The record’s own Next service date is 12 months from the service, with no gas safety anniversary carried over.
  • When the client is a letting agent or a property manager and the property names a landlord, a record prints the landlord’s name and address beside the agent: under Landlord / agent on screen, and in a Landlord column of its own on the printed certificate and the PDF. The landlord is fixed on the record when it is issued, so a record already issued never changes if the property is edited later, and a record from before this existed prints as it always did. A property whose client is the landlord, or a homeowner’s property, prints no landlord line. When the record’s client is a homeowner client, the column is headed Homeowner instead of Landlord / agent; a record with no client prints as it always did.
  • Pick the certificate type in the selector beside Generate on the check page; a check can carry more than one type, such as a CP12 plus a CP14.
  • When the certificate is made: as the engineer submits a signed check, for someone who works alone and for a team, unless the owner has switched on The office checks each certificate before it goes out under Settings, Gas safety certificates. With it on, the submitted check is flagged Certificate to issue in Needs attention on Today and Work, and the office generates it from the check page. A team engineer opens the certificate made at submit by its link (Open the certificate), and sends the landlord or agent their copy from the done screen.

Immutability and PDFs

  • Records are immutable once created and generation is idempotent per check.
  • Replacing a record: an issued record is never changed. When one was issued with a mistake (a wrong Gas Safe number, appliance result or address, say), an owner or office user opens it and chooses Issue a replacement. Manifold opens a corrected copy of its check, with the same property, engineer, date, readings and appliances and no signatures, for the engineer to put right, sign and submit. The replacement can be generated only once the engineer has signed and submitted it. On the engineer’s run and at the top of the check it reads Correcting and the old record’s reference, never Visit overdue. It is the same visit, so the defects found then carry over to it, one per finding, with any quote or progress they have (a defect the correction no longer finds is resolved as recorded in error), and the warning notice (CP14) given then still stands, so the engineer is not asked for another; a new notice made on the correction replaces it. The record it makes replaces the old one, which is kept exactly as it was issued and marked Replaced, naming the new reference, on its page, its PDF, the Records list, the property page and the client portal. The property’s compliance follows the replacement, and a correction never books another check or moves the property’s dates back. A replaced record cannot be sent again; send the replacement. A record can be replaced once, and only one corrected check can be open for it at a time.
  • The public link of a replaced record no longer shows the certificate: it says the certificate has been replaced and asks the visitor to get the current one from their landlord or letting agent. The replacement has its own link.
  • PDFs render with a headless engine, so there is no browser dependency and output is serverless-safe.
  • Download a single record from its page, or a per-property record pack (Download pack (PDF) on the property page) bundling the 50 most recent certificates.
  • A certificate prints on A4 landscape. The firm chooses its layout under Settings, Organisation, Gas safety certificates: Modern, the layout described here and what every firm starts on, or Traditional, a ruled grid laid out like a CP12 pad. The layout sets the PDF and the printed copy; the record page on screen is the same for everyone. A certificate issued from now on keeps the layout it was issued in; one issued before the choice existed follows the setting. A firm that has uploaded the Gas Safe logo supplied to it (Settings, Organisation, Gas safety certificates) has it printed in the head of the certificate, beside its business registration number, in both layouts; every certificate, including ones already issued, prints the file uploaded now. Your business name, address and contact details head it, with the record’s title and reference and, where the business’s Gas Safe registration number is not the engineer’s own number, a Gas Safe registered box. Then come the summary; the property, the landlord or agent and the engineer across the page; a block for each appliance, with its name, type, location and flue on the top line beside the result and Safe to use, and each reading and test under its own label; the engineer’s notes; a long list of defects full width, two to a row; and along the bottom the gas tightness test, the defects and remedial actions (a record with none says None for both) and the signatures side by side, with the disclaimer and the Generated line in the footer. A result or CO reading left blank prints as a dash; an optional reading, a test or a CO alarm that was not recorded has no box at all. Every page is numbered (Page 1 of 2), and a second page is headed with the record and its reference, continued. A typical record, up to about four appliances and two defects, is one page, and one with one or two appliances is set a little larger; a longer one carries on to a second landscape page, never splitting an appliance, a defect or the signatures. The PDF (Download PDF, the landlord or agent email and the record pack) and Print / Save as PDF from the record page or the public link use the same layout; a printed copy has the disclaimer once, at the end. On screen and on a phone the record has the same blocks and sections, stacked to fit the width, with a blank reading as Not recorded. A CP14 warning notice keeps its own layout.
  • Every record, on paper and on its public link, is headed by the business that issued it: your logo when you have uploaded one (Settings, then Organisation), the business name and contact details as they were when the record was issued, and the record’s title and reference on the right. Manifold appears only as Sent using Manifold in the footer; the disclaimer stays at the foot.
  • The document palette is fixed so records look identical regardless of console theme.
  • Text on a record wraps between words. An email address, a link, a reference or a figure is never split across two lines unless it is too long for one, a postcode stays on one line, and on an appliance’s block the result, Safe to use and its answer each have room to read on their own.
  • Each record has a public link that can be turned off and on from the record page (Turn link off and Turn link on); links do not expire on their own. The tenant and the landlord or agent are emailed the same link, so turning it off stops it for both, and Send and Resend are refused while it is off, so nobody is emailed a link that does not open. Records are kept for at least six years. Manifold never deletes one on its own; after six years, one is deleted only when you ask Manifold to or when the workspace is closed. From five years old the Records list marks them archive soon.

Troubleshooting

  • Wrong certificate type: check the Certificate type selector beside Generate before clicking; a generated record cannot be changed, but the right type can still be generated alongside it.
  • Record pack missing a certificate: confirm each underlying check has a generated record.
  • PDF download fails: retry, then confirm the record generated successfully before re-downloading.

Certificates From Before Manifold

Old certificate PDFs belong next to the new ones. Upload them on the property page, or in bulk from Properties, then Certificate archive, and Manifold files them against the property. Extract details then reads the PDF and proposes its dates, type, reference and result for you to confirm; confirming moves the property’s renewal cycle on to those dates (never back, for a certificate older than its last check) and keeps the visit as an imported past check.

  • An archived certificate is history: it is never re-issued, and Manifold never generates a certificate from it.
  • See Import your data from Gas Engineer Software for the bulk upload, the file-name matching and the Needs review list.

Review Before You Generate

Records are immutable once created, so the review step is where quality is enforced. Generate only when the appliance results, defects, photos, and signatures tell a complete and defensible story.

  • Confirm each appliance has the readings its type requires.
  • Confirm defect categories (AR, ID, NCS) and remedial actions are correct.
  • Confirm the engineer signature is present and the certificate identity is right.
  • Resolve anything ambiguous with the engineer before generating, not after.

Why Immutability Helps

A record that cannot be quietly edited after the fact is what makes it trustworthy evidence. Manifold leans into this: generation is idempotent per check, and corrections happen by completing a new check from corrected source data rather than by editing or regenerating the record.

Troubleshooting

  • If a record is wrong, do not look for an edit or regenerate button; correct the source data and complete a new check, which produces a new record.
  • If a record pack is missing a certificate, confirm each underlying check has generated its record.
  • If generation is blocked, read the reason after Not ready to generate under the button: the check is missing an overall result or an appliance result, a Satisfactory verdict has an unsafe appliance, a CP12 has no landlord or agent address, or a senior review is still open.